Software Upgrade Notice

On August 8th, 2015, posted in: NEWS by Comments Off on Software Upgrade Notice

Our Valued Customers,

Thank you for your supports and choosing Weintek products.
This is a software update notification and we would like to inform you about this update.

 

We have released our software listed below:

  1. EasyBuilder Pro V5.02.01 (Build 2015.08.06)

You can find release notes and download the software in the information below.

  1. EasyBuilder Pro V5.02.01 (Build 2015.08.06)

 

Software version: V5.02.01 Build 2015.08.06

Software download: EBproV50201_20150806.zip (click to download; 198.70MB)

Release notes: EBProV50201_ReleaseNotes_20150806_en.pdf (click to download)

 

New Features

EasyBuilder Pro

  1. Added the following new features in macro editor.
  2. Added Y-Scale feature in Trend Display object.
  3. Added several system registers for connection status.
  4. Added more specific explanation of PLC communication error codes.
  5. Added [Password free] check box in System Parameter Setting. The client can connect with HMI without entering a password.
  6. Added macro function BCC(). This function calculates BBC (Block Check Character) to facilitate error detection.
  7. Added [Center in Window] editing tools for centering objects horizontally / vertically in window.
  8. Added Pie Chart object. This object is divided into slices to illustrate numerical proportion.
  9. Added [Follow] check box in the Notification group box in Event Log settings. The notification address will reset to the original state once the alarm condition returns to normal.
  10. Added QR Code object. This object codes texts into QR codes and displays them.
  11. Added [High priority] check box in Data Sampling settings dialog box. Data sampling processes with this feature enabled will be prioritized. Please note that too many priorities can slow down update rate of other objects.
  12. The milliseconds field can be omitted in the backed-up CSV file of Data Sampling.
  13. Added EasyAccess 2.0 server location in System Parameter Settings. Current location includes Global and China.
  14. Network time server of Time sync supports Domain Name (e.g. 0.pool.ntp.org) in System Parameter Settings.
  15. Added [Bit combination] mode in [Word Lamp].

 

Corrections

EasyBuilder Pro

  1. Fixed the problem where the mouse cursor is hidden when [With each operation from a button, a sound is emitted.] is selected.
  2. Fixed the problem where hot swapping USB drive may cause error in writing data to EM address.
  3. Fixed the problem where Address Tags imported cannot apply correctly to remote PLC addresses.
  4. Fixed the problem where Pass-through with MT8090XE and Mitsubishi FX3U PLC is not possible.
  5. Fixed the problem that causes recipe import /export to interpret csv files with multi-lined text or those modified in Excel incorrectly.
  6. Fixed the problem where the wait_time parameter of macro function INPORT2() is not effective.
  7. Fixed the problem where the project files using Tag PLC cannot be correctly decompiled.
  8. Fixed the problem where if Indirect Windows object uses window offset, it will not show the window when the initial read value is zero.

cMT Viewer

  1. cMT Viewer for Windows and cMT-iV5 are updated to version 1.5.4.
  2. Fixed the problem where if Adjust cMT Viewer to windows size is not used and there is window scroll bar for cMT Viewer, users cannot enter information in Numeric Input and ASCII Input objects.
  3. Fixed the problem where opening projects on older OS of cMT-SVR will fail.
  4. Fixed the problem where unknown error will occur if cMT-iV5 is disconnected from cMT-SVR.

 

Drivers

  1. Added Mitsubishi FX5U (Ethernet) driver.
  2. Moeller XC-CPU101 driver added MX device type.
  3. BACnet BACnet/IP driver added Export Tag function to export tag information. Exported tags can be imported to another project.
  4. Rockwell Free Tag Names drivers added error check dialog. If there is an error during tag importing, it will show invalid tags and can export the error information.
  5. Fixed the problem where data cannot be completely transferred from Recipe Database to Beckhoff TwinCAT PLC (Ethernet) – Free Tag Names device type.

 

See release notes PDF file for complete information.

 

Best regards,

 

Technical Support Team

Weintek HMI Corp..

W: weintekHMI.com

T: (510) 897-6670

F: (877) 631-8898

A: 46734 Fremont Blvd., Freomont CA 94538